Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24.240
Filtrar
1.
Am J Case Rep ; 25: e943042, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38627956

RESUMO

BACKGROUND A paradoxical air embolism (PAE) occurs when air entering the central venous circulation reaches the systemic circulation, occurring through an intracardiac shunt or intrapulmonary shunting. Patients presenting for liver transplantation often have intrapulmonary shunting due to pulmonary arterial vasodilation, even in the absence of hepatopulmonary syndrome. Here, we present a case of hemodynamic collapse believed to be caused by a PAE, which was diagnosed intraoperatively with transesophageal echocardiography (TEE). CASE REPORT A 60-year-old man who was diagnosed with non-alcoholic steatohepatitis cirrhosis presented for deceased donor orthotopic liver transplantation with utilization of normothermic machine perfusion. Following reperfusion of the liver allograft, TEE detected intrapulmonary shunting resulting in air within the left atrium, left ventricle, and ascending aorta. The patient developed severe biventricular dysfunction with ST-segment changes on electrocardiography monitoring and became acutely hypotensive with significant hepatic congestion 5 min after liver reperfusion. High doses of inotropic and vasopressor support were used as well as inhaled nitric oxide. The patient recovered after 30 min of medical management. The liver transplantation operation was successfully completed and the patient was discharged home on postoperative day 7. CONCLUSIONS Intracardiac air at the time of reperfusion during liver transplantation can originate from the donor allograft and result in PAE in the setting of intrapulmonary shunting. PAE can result in intracoronary air and should be considered in cases of hemodynamic instability in liver transplantation, especially if air is seen within the left atrium, left ventricle, and ascending aorta.


Assuntos
Embolia Aérea , Transplante de Fígado , Masculino , Humanos , Pessoa de Meia-Idade , Transplante de Fígado/efeitos adversos , Embolia Aérea/etiologia , Cirrose Hepática/complicações , Ecocardiografia Transesofagiana
2.
Ann Card Anaesth ; 27(2): 159-161, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38607880

RESUMO

ABSTRACT: The elephant trunk procedure, an endovascular strategy for retrograde type A acute aortic dissection, is associated with several complications, hemolytic anemia being a rare one. We performed endovascular stent-graft insertion in a patient who developed hemolytic anemia. Transesophageal echocardiography (TEE) detected turbulent jet flow and stenosis position, which was not detected by angiography and intravascular ultrasound (IVUS). This imaging technique proved effective for malperfusion diagnosis and enabled us to confirm its resolution after the endovascular procedure. Intraoperative TEE is a useful adjunct to angiography and IVUS for diagnosis and therapeutic assessment during endovascular repair of a stenosed elephant trunk.


Assuntos
Anemia Hemolítica , Dissecção Aórtica , Humanos , Ecocardiografia Transesofagiana , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Ecocardiografia , Angiografia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Constrição Patológica
3.
Kardiologiia ; 64(3): 40-45, 2024 Mar 31.
Artigo em Russo, Inglês | MEDLINE | ID: mdl-38597761

RESUMO

AIM: Comparative analysis of the height of atherosclerotic plaques (AP) in the descending thoracic aorta (TA) according to two-dimensional (2D) and three-dimensional (3D) transesophageal echocardiography (TEE), and contrast-enhanced multislice computed tomography (MSCT). MATERIAL AND METHODS: The TA was examined using 2D, 3D TEE and contrast-enhanced MSCT in 34 patients (20 men and 14 women aged 68 [62; 71] years). AP heights were compared using the Bland-Altman method and the Spearman correlation analysis. This was a blinded comparative study which assessed the AP morphometry using each of the radiation modalities without knowing the results of the method being compared. RESULTS: 100 APs were examined in the descending TA. The mean height of all analyzed APs in the descending TA was 2.2 mm [2; 2.7] for 2D TEE, 3.1 mm [2.7; 3.55] for 3D TEE, and 3.05 mm [2.55; 3.55] for MSCT. The AP heights measured with 2D TEE was statistically significantly smaller than the heights of similar APs measured either with 3D TEE or MSCT. The mean difference (bias) was 0.88±0.34 mm between 2D and 3D TEE, and 0.83±0.41 mm between 2D TEE and MSCT. The correlation coefficients for the AP heights were r=0.87 (p<0.001) between 2D and 3D TEE and r=0.86 (p<0.001) between 2D TEE and MSCT. There were no differences in the height of similar APs between 3D TEE and MSCT. CONCLUSION: The three-dimensional reconstruction of AP in the TA by TEE is more accurate for quantitative assessment of AP than a two-dimensional study.


Assuntos
Ecocardiografia Tridimensional , Placa Aterosclerótica , Masculino , Humanos , Feminino , Aorta Torácica/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Ecocardiografia , Ecocardiografia Transesofagiana
4.
West J Emerg Med ; 25(2): 166-174, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38596913

RESUMO

Introduction: Intra-arrest transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) have been introduced in adult patients with cardiac arrest (CA). Whether the diagnostic performance of TTE or TEE is superior during resuscitation is unclear. We conducted a systematic review following PRISMA guidelines. Methods: We searched databases from PubMed, Embase, and Google Scholar and evaluated articles with intra-arrest TTE and TEE in adult patients with non-traumatic CA. Two authors independently screened and selected articles for inclusion; they then dual-extracted study characteristics and target conditions (pericardial effusion, aortic dissection, pulmonary embolism, myocardial infarction, hypovolemia, left ventricular dysfunction, and sonographic cardiac activity). We performed quality assessment using the Quality Assessment of Diagnostic Accuracy Studies Version 2 criteria. Results: A total of 27 studies were included: 14 studies with 2,145 patients assessed TTE; and 16 with 556 patients assessed TEE. A high risk of bias or applicability concerns in at least one domain was present in 20 studies (74%). Both TTE and TEE found positive findings in nearly one-half of the patients. The etiology of CA was identified in 13% (271/2,145), and intervention was performed in 38% (102/271) of patients in the TTE group. In patients who received TEE, the etiology was identified in 43% (239/556), and intervention was performed in 28% (68/239). In the TEE group, a higher incidence regarding the etiology of CA was observed, particularly for those with aortic dissection. However, the outcome of those with aortic dissection in the TEE group was poor. Conclusion: While TEE could identify more causes of CA than TTE, sonographic cardiac activity was reported much more in the TTE group. The impact of TTE and TEE on the return of spontaneous circulation and further survival was still inconclusive in the current dataset.


Assuntos
Dissecção Aórtica , Disfunção Ventricular Esquerda , Adulto , Humanos , Ecocardiografia , Ecocardiografia Transesofagiana , Ressuscitação , Dissecção Aórtica/diagnóstico por imagem
6.
Echocardiography ; 41(3): e15785, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38527004

RESUMO

BACKGROUND: Trans-catheter mitral valve replacement (TMVR) procedures had emerged as an alternative solution for patients who are at high risk for mitral valve surgery. Although cardiac computed tomography (CT) remains the standard method for procedural planning, there is no full agreement on the best systolic phase for quantitation of the neoLVOT. Furthermore, a new three-dimensional trans-esophageal echocardiography (3DTEE) based software was developed to serve as filter and or an alternative for patients who cannot have CT due to any contraindication. AIM: To determine the systolic phase of the cardiac cycle that shows the narrowest NeoLVOT area in order to standardize the way of using these software and then to validate the 3DTEE-based software against the CT-based one as a gold standard, in mitral valve annulus (MA) and NeoLVOT assessment. METHODS: A single center, observational, retrospective study. Initially, a sample of 20 patients (age 62 ± 4 years, 70% men) had CT-based analysis at mid-diastole (80%), early-systole (10%), mid-systole (20%), late-systole (30%-40%), in order to detect the best systolic phase at which the neoLVOT area is the narrowest after TMVR. Then, the end systolic phase was standardized for the analysis of 49 patients (age 57 ± 6 years, 60% men), using both the commercially available CT-based software and the newly available 3DTEE-based software (3mensio Structural Heart, Pie Medical Imaging, The Netherlands). The 3DTEE derived parameters were compared with the gold standard CT-based measurements. RESULTS: The neoLVOT area was significantly narrower at end-systole (224 ± 62 mm2), compared to early-systole (299 ± 70 mm2) and mid-systole (261 ± 75 mm2), (p = .005). Excellent correlation was found between 3DTEE and CT measurements for MA AP diameter (r = .96), IC diameter (r = .92), MA area (r = .96), MA perimeter (r = .94) and NeoLVOT area (r = .96), (all p-values < .0001). Virtual valve sizing was based on annulus measurement and was identical between CT and 3DTEE. Interobserver and intraobserver agreements were excellent for all the measurements with ICCs > .80. CONCLUSIONS: End-systole is the phase that shows the narrowest neoLVOT and hence should be the standard phase used during the analysis. The 3DTEE based analysis using this new software is reliable compared to the CT-based analysis and can be serve as an alternative analysis tool in patients who cannot have CT for any clinical contraindication or as a screening test and/or filter for all patients before proceeding to a detailed CT scan.


Assuntos
Ecocardiografia Tridimensional , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cateteres , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Padrões de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos
7.
Catheter Cardiovasc Interv ; 103(5): 741-750, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38451154

RESUMO

BACKGROUND: The GCA is a well performing device in terms of efficacy despite complex anatomies (aortic rim <5 mm and ASD diameter >17 mm) with a good safety profile. AIMS: To evaluate atrial septal defect (ASD) features impacting on right disc device thrombosis in patients who underwent Gore Cardioform ASD Occluder (GCA) implantation. METHODS: A total of 44 consecutive patients undergoing percutaneous ASD with GCA device from January 2020 to September 2022 at our tertiary care Center were evaluated. The minimum follow-up was 6 months. RESULTS: The patients were stratified in two groups according to a cut-off value of ASD diameter equal to 20 mm at sizing balloon, derived from ROC analysis (AUC = 0.894; p = 0.024). Baseline characteristics were comparable between groups in terms of age, sex, weight, height, and interatrial septum dimensions. Patients with ASD > 20 mm (n = 9) had a higher ASD/device dimension ratio, both at echocardiography (p = 0.009) and at sizing balloon (p = 0.001), longer fluoroscopic time (p = 0.022), and higher incidence of device thrombosis (0.006). Right disc thrombosis was observed in three patients of the ASD > 20 mm group, always in the inferior portion of the right disc. On univariate analysis, ASD diameter at sizing balloon (OR 1.360; p = 0.036) was the only positive predictor of device thrombosis. CONCLUSIONS: Right disc thrombosis of the GCA device may be under-recognized at follow-up, hence deserving clinical attention, especially in those patients with larger ASD diameters.


Assuntos
Comunicação Interatrial , Dispositivo para Oclusão Septal , Humanos , Ecocardiografia Transesofagiana , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/terapia
9.
Sci Rep ; 14(1): 5860, 2024 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-38467726

RESUMO

Atrial fibrillation (AF) is the most common human arrhythmia, forming thrombi mostly in the left atrial appendage (LAA). However, the relation between LAA morphology, blood patterns and clot formation is not yet fully understood. Furthermore, the impact of anatomical structures like the pulmonary veins (PVs) have not been thoroughly studied due to data acquisition difficulties. In-silico studies with flow simulations provide a detailed analysis of blood flow patterns under different boundary conditions, but a limited number of cases have been reported in the literature. To address these gaps, we investigated the influence of PVs on LA blood flow patterns and thrombus formation risk through computational fluid dynamics simulations conducted on a sizeable cohort of 130 patients, establishing the largest cohort of patient-specific LA fluid simulations reported to date. The investigation encompassed an in-depth analysis of several parameters, including pulmonary vein orientation (e.g., angles) and configuration (e.g., number), LAA and LA volumes as well as their ratio, flow, and mass-less particles. Our findings highlight the total number of particles within the LAA as a key parameter for distinguishing between the thrombus and non-thrombus groups. Moreover, the angles between the different PVs play an important role to determine the flow going inside the LAA and consequently the risk of thrombus formation. The alignment between the LAA and the main direction of the left superior pulmonary vein, or the position of the right pulmonary vein when it exhibits greater inclination, had an impact to distinguish the control group vs. the thrombus group. These insights shed light on the intricate relationship between PV configuration, LAA morphology, and thrombus formation, underscoring the importance of comprehensive blood flow pattern analyses.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Veias Pulmonares , Trombose , Humanos , Apêndice Atrial/diagnóstico por imagem , Veias Pulmonares/diagnóstico por imagem , Ecocardiografia Transesofagiana , Átrios do Coração/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem
10.
J Cardiothorac Surg ; 19(1): 139, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38504295

RESUMO

BACKGROUND: Left atrial dissection (LAtD) is a rare but potentially life-threatening complication of mitral valve surgery. Its management is not well stablished in the literature. However, early recognition through intraoperative TEE and attention to changes in the left atrial free wall during saline leak testing can lead to avoidance of severe complications. CASE PRESENTATION: We report a case of LAtD detected by intraoperative transesophageal echocardiogram (TEE) following mitral valve repair for primary mitral valve regurgitation secondary to degenerative mitral valve disease with MAZE IV procedure for atrial fibrillation. LAtD was noted on TEE as an expanding double density along the wall of the left atrium with a jet originating at the posterior annulus flowing into the LAtD which was repaired. Separation from bypass following LAtD repair was complicated by severe biventricular dysfunction requiring significant inotropic support and placement of an intra-aortic balloon pump (IABP). Patient's post-operative course was further complicated by right sided heart failure requiring placement of a right sided impella which was subsequently removed on POD 4. Patient was discharged home on POD 17. Transthoracic echo at 1 month, 3 months demonstrated resolution of the LAtD. A follow up echo at 4 years showed complete resolution of the LAtD with an intact mitral repair, trace mitral regurgitation, and a mean gradient across the repair of 3 mm Hg. CONCLUSIONS: Left atrial dissection is a rare but serious complication of mitral valve surgery. We provide a review of the current literature regarding LAtD, emphasizing the need to consider this complication early during mitral surgery to allow for uncomplicated repair.


Assuntos
Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Mitral , Humanos , Átrios do Coração/cirurgia , Átrios do Coração/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Ecocardiografia Transesofagiana , Fibrilação Atrial/complicações
11.
J Cardiothorac Surg ; 19(1): 137, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38504353

RESUMO

BACKGROUND: Paradoxical embolism is a rare cause of acute arterial occlusion. This phenomenon arises when embolic material travels from the venous system crosses an abnormal shunt such as patent foramen ovale, atrial septal defects, ventricular septal defects, or pulmonary arteriovenous malformations, into the arterial system. Impending paradoxical embolism refers to the presence of an entrapped thrombus in the patent foramen ovale. CASE PRESENTATION: We report a case of a 68-year-old female patient who presented with an impending paradoxical embolism, alongside both concomitant pulmonary embolism and myocardial infarction with ST-segment elevation. Swiftly addressed through emergency cardiac surgery and systemic anticoagulation, the patient's condition was effectively treated. CONCLUSIONS: While the ideal treatment strategy for impending paradoxical embolism remains a topic of debate due to limited and inconclusive evidence, emergent open surgery should be contemplated in patients as it signifies a critical clinical emergency.


Assuntos
Embolia Paradoxal , Forame Oval Patente , Infarto do Miocárdio , Embolia Pulmonar , Feminino , Humanos , Idoso , Forame Oval Patente/complicações , Forame Oval Patente/cirurgia , Embolia Paradoxal/complicações , Embolia Paradoxal/cirurgia , Ecocardiografia Transesofagiana , Embolia Pulmonar/complicações , Embolia Pulmonar/cirurgia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/cirurgia
12.
J Cardiovasc Med (Hagerstown) ; 25(4): 311-317, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38488065

RESUMO

AIMS: We present the experience and long-term results of intracardiac echocardiography (ICE)-guided closure of ostium secundum atrial septal defects (ASDs) in two Italian centers and investigate its systematic applicability as the gold standard in routine clinical practice. METHODS: We retrospectively evaluated all consecutive patients who underwent an ASD percutaneous closure procedure from March 2008 to February 2020. All patients underwent a preprocedural transesophageal echocardiography (TEE) evaluation. The closures were carried out under fluoroscopic and ICE guidance. A follow-up visit was performed at 1, 3 and 12 months, followed by telephone evaluations approximately every 2 years. RESULTS: Sixty-six patients (29% male individuals), mean age 43 ±â€Š16 years, were treated. In 15 cases, the TEE defect diameter was less than 10 mm, and in 8 of these patients, the ICE intraprocedural sizing increased the maximum diameter by more than 5 mm. Sizing balloon of the defect was performed in 51 cases; 2 patients received an ASD 38 mm device. Eight patients had multiple defects; in three of these, it was necessary to apply two devices. Four patients showed nonsignificant residual shunt; no complications related to the use of ICE were observed. One patient presented the migration of the ASD device into the abdominal aorta, percutaneously retrieved with a snare. No major complications were recorded during the entire follow-up period. CONCLUSION: This study confirms that ICE monitoring during ASD percutaneous closure is well tolerated and effective; it might be achievable as a routine gold standard by operators willing to use ICE systematically in all transcatheter closure interventions of interatrial communications.


Assuntos
Cateterismo Cardíaco , Comunicação Interatrial , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/terapia , Ecocardiografia Transesofagiana , Fluoroscopia , Resultado do Tratamento
13.
Rev. esp. anestesiol. reanim ; 71(3): 257-260, Mar. 2024. ilus
Artigo em Espanhol | IBECS | ID: ibc-230933

RESUMO

Un varón de 61 años sin predisposición trombótica es sometido a trasplante bipulmonar como último tratamiento para su EPOC terminal sin soporte de ECMO. Tras el implante y la reperfusión de ambos pulmones, se realizó un examen ecocardiográfico transesofágico completo para comprobar principalmente las anastomosis de las venas pulmonares. En este estudio se identificó una gran masa móvil, hiperecogénica, densa y heterogénea en la aurícula izquierda, compatible con un trombo en tránsito desde la circulación venosa pulmonar. Este hallazgo fue comunicado al equipo quirúrgico inmediatamente para reabrir la anastomosis y retirar el coágulo antes de mayores consecuencias. No hubo manifestaciones clínicas cuando se despertó al paciente.(AU)


61-year-old man without any thrombotic predisposition was undergone double sequential lung transplantation due to terminal stage of COPD without extracorporeal membrane oxygenation (ECMO) support. After implantation and reperfusion of both lungs, a complete transoesophageal echocardiography exam was performed to check especially the pulmonary venous anastomosis. In this exam, a large heterogenous, dense, hyperechoic mobile mass was identified in the LA, which was compatible with a thrombus in transit from pulmonary veins circulation. This finding was communicated to the surgical team to reopen the anastomosis and remove the clot before further consequences. There were no clinical manifestations when the patient was awakened.(AU)


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Ecocardiografia Transesofagiana , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/lesões , Trombose , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Transplante de Pulmão , Anestesiologia , Pacientes Internados , Exame Físico , Transplantes
14.
Echocardiography ; 41(3): e15798, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38516863

RESUMO

Editing of 3D raw images acquired during transesophageal echocardiography could be similar to the post processing of raw images with digital software used in photography. 3D image editing in echocardiography is often underestimated in clinical practice, and people are satisfied with the first 3D image they are able to obtain during transesophageal examination. In fact, it is often believed to represent solely an aesthetic addition that does not change the information already obtained with 2D and baseline 3D. In reality, it represents a crucial moment to better understand the mechanisms of mitral pathology, avoiding artifacts and misjudgments. The importance of acquiring raw 3D images of the valve having all the necessary information (ring, the leaflet in toto, the right frame rate) allows us then to edit them making them more beautiful and clearer from the point of view of the information received. Nevertheless, by exclusively acquiring a raw 3D with all the necessary information, we can quickly finish the transesophageal examination, reducing its duration and discomfort for the patient, as well as the inherent risk of complications related to the procedure per se.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ecocardiografia/métodos , Ecocardiografia Transesofagiana/métodos , Fotografação
15.
Echocardiography ; 41(3): e15799, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38516862

RESUMO

Atherosclerosis is the most common cause of heart disease and stroke. Plaque thickness ≥4 mm in the ascending aorta or aortic arch is strongly correlated with cerebral embolic events and ischemic stroke. However, despite imaging workup, the cause of embolic stroke remains unidentified in many patients. Transesophageal echocardiography (TEE) is the preferred echocardiographic method for the evaluation of cardiac source of emboli. 2D TEE imaging evaluates aortic root and aortic arch in a single plane or two planes with biplane imaging. However, 2D TEE often fails to detect mobile or complex components in the ascending aorta and aortic arch plaques. The routine availability of 3D TEE in current ultrasound systems may significantly improve the assessment of aortic plaques as a potential embolic source. In this case series, we present four consecutive patients with stroke who underwent TEE by a single cardiologist for possible cardioembolic source. Some of these patients may have been labelled as "cryptogenic stroke" or "embolic stroke of undetermined source" (ESUS) due to the presence of insignificant or nonmobile ascending aortic or aortic arch plaques on 2D TEE imaging. In our four consecutive patients with ESUS who underwent TEE by a single operator, 3D TEE showed complex aortic arch plaques with ulceration with mobile components and established these plaques as the likely source of embolic stroke.


Assuntos
Doenças da Aorta , Aterosclerose , AVC Embólico , Embolia , Placa Aterosclerótica , Acidente Vascular Cerebral , Humanos , Placa Aterosclerótica/complicações , Placa Aterosclerótica/diagnóstico por imagem , Ecocardiografia Transesofagiana/métodos , AVC Embólico/complicações , Aterosclerose/complicações , Aterosclerose/diagnóstico por imagem , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/diagnóstico por imagem , Aorta Torácica/diagnóstico por imagem , Embolia/complicações , Doenças da Aorta/complicações , Doenças da Aorta/diagnóstico por imagem
17.
Kyobu Geka ; 77(1): 27-33, 2024 Jan.
Artigo em Japonês | MEDLINE | ID: mdl-38459842

RESUMO

BACKGROUND: Occlusion of the left atrial appendage( LAA) may prevent stroke in patients with atrial fibrillation. In this study, we reviewed various types of LAA occlusion techniques and results of patients underwent surgical LAA closure. METHODS: Between 2004 and 2022, 182 patients who underwent surgical LAA closure were enrolled in this study. RESULTS: The surgical LAA closure consisted of 90 cases of closure device, AtriCure, 63 cases of surgical excision, 13 cases of stapler excision, 3 cases of ligation, and 13 cases of internal suture ligation. During the follow-up period, there were no deaths owing to cardiogenic emboli and no cerebral infarctions. CONCLUSIONS: Regardless of the surgical techniques, LAA closure was effective in preventing cardiogenic stroke. The AtriClip is a safe, simple, and effective and thoracoscopic LAA closure using AtriClip is expected as a less-invasive LAA management.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Acidente Vascular Cerebral , Humanos , Resultado do Tratamento , 60589 , Procedimentos Cirúrgicos Cardíacos/métodos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fibrilação Atrial/cirurgia , Apêndice Atrial/cirurgia , Ecocardiografia Transesofagiana
18.
Kardiol Pol ; 82(3): 303-307, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38493455

RESUMO

BACKGROUND: The correlation between atrial septum anatomy and the risk of ischemic neurological events remains underexplored. AIMS: This study aimed to examine both the functional and anatomical attributes of the atrial septum and identify predictors of stroke and/or transient ischemic attack (TIA) in patients diagnosed with patent foramen ovale (PFO). METHODS: A total of 155 patients diagnosed with PFO, with a cardiological cause of neurological events, were enrolled. Transesophageal echocardiography was utilized to assess the anatomy of the PFO canal, size of the right-to-left shunt, thickness of the primary and secondary atrial septum, presence of atrial septum aneurysm, and anatomical structures of the right atrium. RESULTS: Regression analysis showed that factors such as female sex, hypercholesterolemia, PFO canal width, and a large right-to-left shunt were significantly associated with stroke and/or TIA. Receiver operating characteristic analysis indicated that the width of the PFO canal holds a relatively weak, although significant predictive, value for ischemic neurological episodes (area under the curve = 0.7; P = 0.002). A PFO canal width of 4 mm was associated with 70% sensitivity and 55% specificity for predicting stroke and/or TIA. CONCLUSIONS: The atrial septum's anatomy, especially the dimensions of the PFO canal and the magnitude of the right-to-left shunt, combined with specific demographic and clinical factors, are linked to ischemic neurological incidents in PFO patients.


Assuntos
Septo Interatrial , Forame Oval Patente , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Humanos , Feminino , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico por imagem , Septo Interatrial/diagnóstico por imagem , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/complicações , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/complicações , Átrios do Coração/diagnóstico por imagem , Ecocardiografia Transesofagiana/efeitos adversos
19.
Int Heart J ; 65(2): 367-370, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38479845

RESUMO

Papillary fibroelastoma (PFE) is a benign tumor that arises mostly from left-sided valves. PFE can cause stroke, and surgical resection may be needed. Lambl's excrescence (LE) is a filiform valvular lesion and is considered a possible cause of stroke. A 79-year-old man with light-headedness and left-sided hemiparesis was diagnosed with stroke. Transesophageal echocardiography (TEE) revealed a round-shaped mobile mass in the left ventricular outflow tract (LVOT), which was considered the cause of the stroke. Surgical resection was performed transaortically, and during surgery, a mass was incidentally detected on the noncoronary cusp (NCC), which was also resected followed by aortic valve replacement. Pathology confirmed that the mass in the LVOT was a PFE and that the filiform mass on the NCC was LE. We herein report a rare case of PFE in the LVOT and coexisting LE on the NCC. A careful examination via TEE helps to identify other possible causes of stroke hidden behind the obvious cause.


Assuntos
Fibroelastoma Papilar Cardíaco , Neoplasias Cardíacas , Doenças das Valvas Cardíacas , Acidente Vascular Cerebral , Masculino , Humanos , Idoso , Doenças das Valvas Cardíacas/complicações , Fibroelastoma Papilar Cardíaco/complicações , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/patologia , Acidente Vascular Cerebral/complicações , Ecocardiografia Transesofagiana , Neoplasias Cardíacas/diagnóstico , Neoplasias Cardíacas/diagnóstico por imagem
20.
Acta Cardiol ; 79(1): 87-90, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38314756

RESUMO

We present a case of a 79-year-old man on apixaban for atrial fibrillation who suffered multiple ischaemic strokes and was found to have mobile structures attached to his pacemaker lead on transesophageal echocardiography. Based on the Modified Duke Criteria, there was no evidence of infectious endocarditis. Since there were no signs of a patent foramen ovale or arteriovenous malformations in the lungs, the mobile structures probably were not the cause of the ischaemic strokes. After the visualisation of the mobile structures, apixaban was switched to dabigatran with a clear decrease in the size of the structures. Blood cultures remained negative and there was no fever or increase in inflammatory parameters. It was therefore suspected that the structures were thrombus material rather than vegetations of infectious endocarditis.There is uncertainty surrounding the clinical relevance and indication for treatment of incidentally found mobile structures on pacemaker leads. Multiple studies with different imaging modalities show a significant difference in the prevalence of thrombi. More studies with longer follow-ups are needed to investigate the prevalence and need for treatment of these incidentally found structures on pacemaker leads.


Assuntos
Endocardite , Forame Oval Patente , AVC Isquêmico , Marca-Passo Artificial , Masculino , Humanos , Idoso , Marca-Passo Artificial/efeitos adversos , Ecocardiografia Transesofagiana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...